Vulmon
Recent Vulnerabilities
Research Posts
Trends
Blog
About
Contact
Vulmon Alerts
By Relevance
By Risk Score
By Publish Date
schneider-electric citectscada vulnerabilities and exploits
(subscribe to this query)
614
VMScore
CVE-2013-2796
Schneider Electric Vijeo Citect 7.20 and previous versions, CitectSCADA 7.20 and previous versions, and PowerLogic SCADA 7.20 and previous versions allow remote malicious users to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and ...
Schneider-electric Powerlogic Scada 7.10
Schneider-electric Vijeo Citect
Schneider-electric Vijeo Citect 7.10
Schneider-electric Citectscada
Schneider-electric Powerlogic Scada
Schneider-electric Citectscada 7.10
187
VMScore
CVE-2019-10981
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
Schneider-electric Scada Expert Vijeo Citect 7.40
Schneider-electric Scada Expert Vijeo Citect 7.30
Schneider-electric Citectscada 7.40
Schneider-electric Citectscada 7.30
383
VMScore
CVE-2011-4033
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and previous versions, CitectHistorian 4.30 and previous versions, and CitectSCADAReports 4.10 and previous versions, allows remote malicious users to cause a denial of serv...
Schneider-electric Vijeo Historian 4.20
Schneider-electric Vijeo Historian 4.10
Schneider-electric Vijeo Historian 4.0
Schneider-electric Vijeo Historian
Schneider-electric Citecthistorian
Schneider-electric Citecthistorian 4.20
Schneider-electric Citectscada Reports
Schneider-electric Citectscada Reports 4.0
828
VMScore
CVE-2011-4034
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and previous versions, CitectHistorian 4.30 and previous versions, and CitectSCADAReports 4.10 and previous versions, allows remote malicious users to execute arbitrary code...
Schneider-electric Vijeo Historian 4.20
Schneider-electric Vijeo Historian 4.10
Schneider-electric Vijeo Historian 4.0
Schneider-electric Vijeo Historian
Schneider-electric Citecthistorian
Schneider-electric Citecthistorian 4.20
Schneider-electric Citectscada Reports
Schneider-electric Citectscada Reports 4.0
383
VMScore
CVE-2011-4035
Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and previous versions, CitectHistorian 4.30 and previous versions, and CitectSCADAReports 4.10 and previous versions allows remote malicious users to inject arbitrary web script or HTML via unspec...
Schneider-electric Vijeo Historian 4.0
Schneider-electric Vijeo Historian
Schneider-electric Vijeo Historian 4.20
Schneider-electric Vijeo Historian 4.10
Schneider-electric Citecthistorian 4.20
Schneider-electric Citecthistorian
Schneider-electric Citectscada Reports
Schneider-electric Citectscada Reports 4.0
445
VMScore
CVE-2011-4036
Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and previous versions, CitectHistorian 4.30 and previous versions, and CitectSCADAReports 4.10 and previous versions allows remote malicious users to read arbitrary files via unspecified vectors.
Schneider-electric Vijeo Historian 4.20
Schneider-electric Vijeo Historian 4.10
Schneider-electric Vijeo Historian 4.0
Schneider-electric Vijeo Historian
Schneider-electric Citecthistorian 4.20
Schneider-electric Citecthistorian
Schneider-electric Citectscada Reports
Schneider-electric Citectscada Reports 4.0
694
VMScore
CVE-2013-2824
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 up to and including 7.30SP1, CitectSCADA 7.20 up to and including 7.30SP1, StruxureWare PowerSCADA Expert 7.30 up to and including 7.30SR1, and PowerLogic SCADA 7.20 up to and including 7.20SR1 do n...
Schneider-electric Struxureware Scada Expert Vijeo Citect 7.20
Schneider-electric Struxureware Scada Expert Vijeo Citect 7.40
Schneider-electric Struxureware Scada Expert Vijeo Citect 7.30
Schneider-electric Citectscada 7.20
Schneider-electric Struxureware Powerscada Expert 7.30
Schneider-electric Powerlogic Scada 7.20
Schneider-electric Citectscada 7.30
1000
VMScore
CVE-2013-3075
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote malicious users to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a ce...
Mitsubishi-automation Mitsubishi Mx Component 3
Schneider-electric Citectfacilities 7.10
Schneider-electric Citectscada 7.10
1 EDB exploit
409
VMScore
CVE-2011-5163
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA prior to 7.20 and Mitsubishi MX4 SCADA prior to 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
Schneider-electric Citectscada
Mitsubishi-automation Mx4 Scada
392
VMScore
CVE-2015-1014
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectS...
Schneider-electric Opc Factory Server 3.5
VMScore
CVSSv2
CVSSv3
VMScore
Recommendations:
CVE-2024-4761
command injection
CVE-2024-3676
IDOR
CVE-2024-30039
CVE-2024-32113
CVE-2024-30049
CVE-2024-4776
SQL injection
Vulnerability Notification Service
You don’t have to wait for vulnerability scanning results
Get Started